Viessmann Error Code E e0: Viessmann 2-wire BUS communication module cable break (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code E e0 on a boiler means: Viessmann 2-wire BUS communication module cable break. It is also called Viessmann diagnostic code E e0.

Medium severityBoilerVitotronic 200-H

Homeowner? What Viessmann code E e0 means for you

Check, then call Your boiler is reporting: Viessmann 2-wire BUS communication module cable break. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code E e0 mean?

Control mode cable break on the Viessmann 2-wire BUS communication module.

Applies to: Vitotronic 200-H, Model HK1M

Common causes of Viessmann code E e0

  • Break in the 2-wire BUS connection
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code E e0

HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300

Other Viessmann Boiler codes

CodeMeaning
EB 194Repeated flame loss at calibration
ECSafety relay fault
EC 67 or 195Parameter fault at calibration
EDIgnition relay fault
ED 191Internal burner control fault
EEInternal feedback error, gas safety valves
EE 132Flame signal missing or weak at burner start
EEEData record error or out-of-range parameter
EFInternal feedback error, gas safety valves
EF 138Flame lost during safety time
Ext. controlHeating program changed by external control
External Hook-upOperating program changed by external device

All Viessmann Boiler error codes →

Viessmann code E e0: homeowner questions

What does Viessmann code E e0 mean?

Viessmann 2-wire BUS communication module cable break. Control mode cable break on the Viessmann 2-wire BUS communication module.

Is it safe to keep using my boiler with code E e0?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code E e0 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code E e0 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code E e0 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitotronic 200-H installation and service instructions, p. 29. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.