Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Check mixing valve motor rotation direction

Updated · by Aurora Star Tech Inc.

Check mixing valve motor rotation direction on a Viessmann boiler: After power-up the boiler runs a self-test that opens and closes the mixing valve. Then the valve is set manually to Open to confirm the flow temperature rises.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HA extension kit

Common causes of check mixing valve motor rotation direction

  • Motor turning in the wrong direction
  • Mixing valve set incorrectly fitted

How to fix check mixing valve motor rotation direction: step by step

  1. Switch the boiler on and let the self-test run.
  2. Set the mixing valve manually to Open.
  3. Check that the flow temperature sensor reads a higher temperature.
  4. If the temperature drops, reverse the motor or refit the mixing valve set.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitodens 200-W B2HA service instructions, p. 86. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.