Viessmann Boiler: Set maximum output
Set maximum output on a Viessmann boiler: Limits the maximum heating input through the modulation range. The limit cannot exceed the boiler coding card.
Applies to: Vitodens 200-W B2HA 19, 28, 35
How to fix set maximum output: step by step
- Press OK and the second button at the same time for about 4 seconds.
- Select "Service functions".
- Select "Maximum output".
- Select "Yes" at "Change?".
- A value flashes (factory 85 = 100% of rated input).
- Select the required value.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Viessmann Vitodens 200-W B2HA service instructions, p. 19. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.