Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code EB 194: Repeated flame loss at calibration (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code EB 194 on a boiler means: Repeated flame loss at calibration. It is also called Viessmann diagnostic code EB 194.

High severityBoilerVitodens 200-W B2HA

Homeowner? What Viessmann code EB 194 means for you

Call a technician Your boiler is reporting: Repeated flame loss at calibration. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EB 194 mean?

Burner in fault mode. Repeated flame loss during calibration. Detailed code 194.

Applies to: Vitodens 200-W B2HA 45, 60

Common causes of Viessmann code EB 194

  • Gap between ionization electrode and burner gauze wrong
  • Wrong gas type allocation
  • Flue gas recirculation
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
E7 192Ionization current too low at calibration
E8Ionization current outside permissible range
E8 189Ionization current outside permissible range
EAIonization current outside range during calibration
EA 193Ionization current deviation during calibration
EBRepeated flame loss during calibration
ECSafety relay fault
EC 67 or 195Parameter fault at calibration
EDIgnition relay fault
ED 191Internal burner control fault
EEInternal feedback error, gas safety valves
E e0Viessmann 2-wire BUS communication module cable break

All Viessmann Boiler error codes →

Viessmann code EB 194: homeowner questions

What does Viessmann code EB 194 mean?

Repeated flame loss at calibration. Burner in fault mode. Repeated flame loss during calibration. Detailed code 194.

Is it safe to keep using my boiler with code EB 194?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code EB 194 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EB 194 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EB 194 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitodens 200-W B2HA 45, 60 Service Instructions, p. 75. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977