Viessmann Boiler: Open coding level 2 on the Vitotronic 300-K

Updated · by Aurora Star Tech Inc.

Open coding level 2 on the Vitotronic 300-K on a Viessmann boiler: Coding level 2 shows every coding address, including those from level 1. Addresses that do not apply to the installed equipment or to other settings are hidden.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitotronic 300-K coding

How to fix open coding level 2 on the vitotronic 300-k: step by step

  1. Press OK and the second button shown on the page together for about 4 seconds (button symbol is not legible in this extract).
  2. Repeat the same button press for about 4 seconds again.
  3. Confirm that the display shows 'Coding level 2'.
  4. Select the coding group needed: General, Cascade, DHW, Solar, Heating circuit 1/2/3, or All codes std device.
  5. Select the coding address, choose the value from the tables, and confirm with OK.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

MW1SVitotronic 300-K, type MW2B

More access & passwords tips for boiler

Source: Vitotronic 200 and 300-K Installation and Service Instructions, p. 49. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.