Viessmann Boiler: Connect several remote control units (Version 1)
Connect several remote control units (Version 1) on a Viessmann boiler: Several Vitotrol remote controls are connected through a terminal box installed on site.
Applies to: Vitotrol remote controls on KM BUS
How to fix connect several remote control units (version 1): step by step
- Install a terminal box on site.
- Connect the control unit to the terminal box.
- Connect Vitotrol 1, Vitotrol 2 and Vitotrol 3 to the terminal box, following the wiring diagram.
- Keep each branch to the terminal box to a maximum of 15 m / 50 ft.
- Keep the total length of all KM BUS cables to a maximum of 50 m / 164 ft.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitotronic 300, Model GW2 installation and service instructions, p. 110. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.