Viessmann Boiler: Burner does not start or starts intermittently (red fault LED flashes)
Burner does not start or starts intermittently (red fault LED flashes) on a Viessmann boiler: The burner does not light, or it cycles on and off with the red fault LED flashing.
Applies to: Vitotronic 100 KW10B
Common causes of burner does not start or starts intermittently (red fault led flashes)
- Burner is not electrically connected
- Fixed high limit (FHL) has tripped
How to fix burner does not start or starts intermittently (red fault led flashes): step by step
- Make sure the 7-pole plug-in connection to the burner and/or power venter is fully connected.
- Check the fixed high limit. If it has tripped, reset it as described in the reset tip.
- Check that the control does not show a continuous burner call with the override switch on.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Source: Vitotronic 100 KW10B operating manual, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.