Viessmann Boiler: Wire the Hydrostat 3250-Plus burner control
Wire the Hydrostat 3250-Plus burner control on a Viessmann boiler: Field wiring for the Hydrostat 3250-Plus control with a Beckett, Carlin or Riello burner. Power comes in on L1 and N to the high limit control.
Applies to: Hydrostat 3250-Plus with Beckett, Carlin or Riello burner
How to fix wire the hydrostat 3250-plus burner control: step by step
- Disconnect power at the service switch before any wiring work.
- Connect incoming line hot (L1) to terminal L1 and neutral (N) to terminal L2 of the Hydrostat 3250-Plus.
- Secure the burner wiring harness to the boiler side panel with the two cable straps, coiled so there is no slack.
- For Beckett or Carlin burners, cut the burner harness to 6 in. to reach the burner junction box under the primary control.
- For Riello burners, the red wire is not used. Cap both ends with wire nuts, inside the high limit control and at the Riello sub-base.
- Run all 120 VAC wiring in flexible metal conduit and attach it to the 4x4 junction box on the burner, not to the cover mounting plate.
- Provide disconnect means, overload protection, electrical ground and low water cut-off as local codes require.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitorond 100, VR1 Installation and Service Instructions, p. 26. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.