Viessmann Boiler: System layout 4: radiator circuit plus underfloor circuit with mixing valve
System layout 4: radiator circuit plus underfloor circuit with mixing valve on a Viessmann boiler: Direct radiator circuit combined with an underfloor circuit on a 3-way mixing valve, plus DHW. The radiator circuit flow must be at least 30% greater than the underfloor flow, and the total must stay under the boiler maximum.
Applies to: Radiator plus underfloor circuit with mixing valve
How to fix system layout 4: radiator circuit plus underfloor circuit with mixing valve: step by step
- Confirm the radiator circuit flow is at least 30% greater than the underfloor circuit flow.
- Confirm the combined flow of both circuits stays under the page 30 boiler maximum.
- Use a low-loss header if the flow exceeds the page 30 limit or is unknown.
- Install the mixing valve accessory kit to control the 3-way valve.
- Pipe the DHW circulating pump so it pumps into the boiler.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
Source: Vitodens 200-W B2HB installation instructions, p. 36. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.