Updated · by Aurora Star Tech Inc.

Checking heating circuit values on a Viessmann boiler: Heating circuit values show room, flow and pool temperatures plus pump and release status. Room temperature only shows when a sensor or remote room unit (FBR) is connected. Flow temperature is shown for mixed circuits only.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Heating circuits 1 and 2 on the Versatronik 200

How to fix checking heating circuit values: step by step

  1. Read T-Room and Humidity if a room sensor or FBR is connected.
  2. Read T-Flow and the flow set temperature on mixed circuits.
  3. Read Circuit release to confirm the heating circuit is in heating mode.
  4. Read CH Pump to confirm the circuit pump state.
  5. Read Need-Opti-Time to see the last required heat-up time when heat-up optimisation is active.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Versatronik 200 installation and operating manual, p. 99. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.