Viessmann Boiler: Edit a heating time block on the controller

Updated · by Aurora Star Tech Inc.

Edit a heating time block on the controller on a Viessmann boiler: Set the weekday, time block and start/end times for a heating time program. Programs are available for heating circuits 1 and 2 (Prg1 and Prg2), DHW loading and DHW circulation.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Heating circuit time programs

How to fix edit a heating time block on the controller: step by step

  1. Press Home, then select Time Program using the rotary dial and the adjacent key.
  2. Choose the program to edit, for example Heating circuit 2 Prog2.
  3. Use the F button to choose the weekday or block, for example Mo - Fr (Monday to Friday).
  4. Press OK to select a time block, such as 06:00 to 08:00 or 16:00 to 22:00.
  5. Press OK to select the start time, then turn the rotary knob to adjust it.
  6. Press OK to save the new program. Press Cancel to leave a block without saving.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Versatronik 200 installation and operating manual, p. 130. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977