Adjust the adjustable high limit to 100 °C / 212 °F on a Viessmann boiler: Factory setting is 95 °C / 203 °F. Note the coding address 06 setting after adjusting.
Applies to: Vitotronic 100 GC1 adjustable high limit
How to fix adjust the adjustable high limit to 100 °c / 212 °f: step by step
- Disconnect power to the control and burner.
- Using a suitable screwdriver, lever out and remove the selector knob R behind the hinged cover.
- Using pointed pliers, break off the cams marked in the figure from the stop dial.
- Fit the selector knob R so the marking is in the centre of the selected range (75 to 100 °C / 167 to 212 °F).
- Check and note the coding address 06 setting.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
More commissioning tips for boiler
Source: Vitotronic 100, GC1 / Vitocontrol-S VD2/CT3/CM2 installation and service instructions, p. 40. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.