Viessmann Boiler: Accessory power supply and cabling
Accessory power supply and cabling on a Viessmann boiler: Accessory power is connected at the control and switched by the system on/off switch. The Vitotronic 200-H HK1B mixing valve control, the mixing valve accessory kit and the Solartrol control need a separate 120 VAC supply from a wall receptacle. Only one accessory part or switch contact can be connected to a plug contact at a time. Cabling may be needed for an outdoor sensor, HK1B control, mixing valve kit, remote operating mode switching, remote disable, alarm output, wall-mount base, circulating pump and zone thermostats. Cables near the control must not be secured to the control bracket, and cable temperature ratings must not be exceeded.
Applies to: Vitocrossal 300 CU3A electrical connections
How to fix accessory power supply and cabling: step by step
- Connect accessory power at the control; it switches with the system on/off switch.
- Provide a separate 120 VAC wall receptacle supply for HK1B, mixing valve kit and Solartrol.
- Connect only one accessory or switch contact per plug contact.
- Do not secure connecting cables to the control unit bracket.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
CU3I 2ZC2ZP.01CU3I 3HC/Z3ZP.01CU3X 1ZC1ZP.01Vitocrossal 300 CU3A 26Vitocrossal 300 CU3A 35Vitocrossal 300 CU3A 45Vitocrossal 300 CU3A 57Vitocrossal 300 CU3A 94Vitocrossal 300 CU3A 125Vitocrossal 300 CU3A 160Vitocrossal 300 CU3A 199
Source: Vitocrossal 300 CU3A Installation Instructions, p. 56. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.