Updated · by Aurora Star Tech Inc.

Drain the boiler on the DHW side on a Viessmann boiler: Drain the domestic hot water circuit through the drain valve. Make sure the DHW pipework is well ventilated.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DHW side drain

How to fix drain the boiler on the dhw side: step by step

  1. Connect a hose to the drain valve and run it to a suitable container or drain.
  2. Turn the drain valve from lever position A to position B or C as needed.
  3. Position B: drains the drinking water circuit in the appliance, excluding the DHW tank, through the cold water connection.
  4. Position C: drains the potable water circuit and DHW tank through the hot water connection. The cold water connection stays filled.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitodens 222-F B2TB 19, 35, 68, 125 Service Instructions, p. 26. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.