Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Hanging the boiler on the wall bracket

Updated · by Aurora Star Tech Inc.

Hanging the boiler on the wall bracket on a Viessmann boiler: The boiler is hung on the bracket and then levelled. It must be level both ways so condensate drains correctly.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HA 45, 60 wall mounting

How to fix hanging the boiler on the wall bracket: step by step

  1. Remove the external accessories connection box cover.
  2. Loosen the bottom screws without removing them completely.
  3. Remove the front enclosure panel by lifting it up and pulling it away.
  4. Mount the boiler onto the bracket.
  5. Adjust the levelling screws until the boiler is level, checking with a round bubble level on top.
  6. Install the supplied installation fittings per the layout on page 11.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitodens 200-W B2HA 45, 60 Installation Instructions, p. 15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977