Viessmann Boiler: Heating status is off
Heating status is off on a Viessmann boiler: The boiler is not receiving a heat call or the control board has failed.
Applies to: Vitotron 100 VLN2
Common causes of heating status is off
- No thermostat connection
- Thermostat not calling for heat or room is already above set point
- Control board failure
How to fix heating status is off: step by step
- Make sure the thermostat is calling for heat and the room is below the thermostat set point.
- Verify the connections on the thermostat.
- Check the glass fuse on the control panel (6.3 x 32 mm, 2 A).
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
VLN2 04VLN2 06VLN2 08VLN2 12VLN2 14.4
Source: Vitotron 100 installation and service instructions, p. 18. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.