Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: High altitude de-rate

Updated · by Aurora Star Tech Inc.

High altitude de-rate on a Viessmann boiler: At high altitude installation at 10,000 ft the input of models B2HB 45, 57, 160 and 199 is de-rated by 21 percent.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HB 45, 57, 160, 199 at 10,000 ft

How to fix high altitude de-rate: step by step

  1. Apply the 21 percent input de-rate when the boiler is installed at 10,000 ft altitude.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199

More commissioning tips for boiler

Source: Vitodens 200-W B2HB installation manual, p. 61. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977