Viessmann Boiler: Rooms too hot

Updated · by Aurora Star Tech Inc.

Rooms too hot on a Viessmann boiler: Usually a setting problem. A control unit fault or a faulty outside temperature sensor can also cause it.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitotronic 200-H heating circuit

Common causes of rooms too hot

  • Control unit settings incorrect (room temperature, time, heating curve)
  • Control unit fault or faulty outside temperature sensor (fault symbol U flashes)
  • Mixer motor faulty

How to fix rooms too hot: step by step

  1. Check and correct room temperature, time program and heating curve settings.
  2. If the fault symbol U flashes, scan the fault code and notify the heating contractor.
  3. If the mixer motor is faulty: unlock motor lever A and operate mixer lever B by hand, then notify the heating contractor.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300

Source: Vitotronic 200-H operating instructions, p. 16. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.