Viessmann Boiler: Mounting the control unit
Mounting the control unit on a Viessmann boiler: Mounting sequence for the Vitotronic 200-H control unit on a wall.
Applies to: Vitotronic 200-H HK1B
How to fix mounting the control unit: step by step
- Fasten the metal backplate to the mounting surface with four fasteners.
- Position the midplate between the backplate and the connection enclosure.
- Install the midplate and connection enclosure onto the backplate.
- Fasten the connection enclosure and midplate to the backplate with two fasteners.
- Install the control rear section onto the connection enclosure housing. Hook the control onto the backplate tabs and pivot it downwards.
- Fasten the control rear section to the connection enclosure with two fasteners.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300
Source: Vitotronic 200-H HK1B installation and service manual, p. 15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.