Viessmann Boiler: Heat slope adaptation (ON/OFF)
Heat slope adaptation (ON/OFF) on a Viessmann boiler: Automatic heat slope adjustment is active only with the outdoor sensor connected. It runs only below 8°C outdoor and with the room below 18°C. If the room does not reach the target within 4 hours, the adaptation is cancelled and the warning indicator flashes. It then repeats the next day.
Applies to: Versatronik COMO OT
How to fix heat slope adaptation (on/off): step by step
- Connect the outdoor sensor to terminals 5 and 6.
- Turn the adaptation on.
- Allow the system to run through the adaptation.
- If the warning indicator flashes, let the next day's adaptation run.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Versatronik COMO OT installation and operating manual, p. 28. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.