Viessmann Boiler: Accessory power supply at the control
Accessory power supply at the control on a Viessmann boiler: Accessory power can be taken from the control. It switches on and off with the system on/off switch. The Vitotronic 200-H, the HK1B mixing valve control, the mixing valve accessory kit and the Solartrol control each need their own 120 VAC supply from a wall receptacle.
Applies to: Vitocrossal 300 CU3A boiler accessories
How to fix accessory power supply at the control: step by step
- Connect accessory power at the control so it follows the system on/off switch.
- Run a separate 120 VAC wall supply to the Vitotronic 200-H, HK1B, mixing valve kit and Solartrol control.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
CU3I 2ZC2ZP.01CU3I 3HC/Z3ZP.01CU3X 1ZC1ZP.01Vitocrossal 300 CU3A 26Vitocrossal 300 CU3A 35Vitocrossal 300 CU3A 45Vitocrossal 300 CU3A 57Vitocrossal 300 CU3A 94Vitocrossal 300 CU3A 125Vitocrossal 300 CU3A 160Vitocrossal 300 CU3A 199
Source: Vitocrossal 300 CU3A installation instructions, p. 56. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.