Viessmann Boiler: Check fuses (control unit and external accessories box)
Check fuses (control unit and external accessories box) on a Viessmann boiler: Use this to check the control unit fuse and the fuses in the external accessories connection box.
Applies to: Vitodens 200-W B2HB 45, 57, 160, 199
How to fix check fuses (control unit and external accessories box): step by step
- Switch OFF the power.
- Release the side latches and pivot the control unit down.
- Remove cover A.
- Check fuse F1 (see wiring diagram on p. 91).
- To check the external accessories box, switch OFF the power, open the box, and check fuses F1 and F2 (see wiring diagram on p. 91).
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
Source: Vitodens 200-W B2HB service instructions, p. 83. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.