Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Install the DHW tank temperature sensor

Updated · by Aurora Star Tech Inc.

Install the DHW tank temperature sensor on a Viessmann boiler: Fit the sensor on single-boiler systems that heat domestic hot water. Systems without DHW heating must not have this sensor connected.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Single-boiler systems with domestic hot water

How to fix install the dhw tank temperature sensor: step by step

  1. Install the DHW tank temperature sensor following the DHW tank installation instructions.
  2. If the sensor goes into a tank of another make, press it against the sensor well with a suitable device.
  3. Make sure the maximum allowable DHW temperature cannot be exceeded. Fit a suitable safety device if needed.
  4. Connect the sensor per the wiring overview on pages 58 and 59.
  5. On systems without DHW heating, do not connect the DHW tank temperature sensor.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitotronic 100/300-K installation and service instructions, p. 64. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977