Viessmann Boiler: Actuator test procedure
Actuator test procedure on a Viessmann boiler: Actuators are switched on one at a time from the service menu. The service level exits automatically after 30 minutes.
Applies to: Vitotronic 200 and 300-K actuators
How to fix actuator test procedure: step by step
- Press OK and the service button until service appears.
- Scroll to actuator test and select with OK.
- Scroll to the actuator to test and leave it highlighted; its state changes from OFF to ON.
- When finished, press the exit button.
- Note that service mode exits by itself after 30 minutes.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitotronic 200
HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B
Vitotronic 300-K
MW1SVitotronic 300-K, type MW2B
Source: Vitotronic 200 and 300-K Installation and Service Instructions, p. 31. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.