Viessmann Boiler: Control connections and cable routing
Control connections and cable routing on a Viessmann boiler: Cabling is needed for the outdoor sensor, Vitotronic 200-H HK1B, the mixing valve kit, remote operating mode switching, remote disable, alarm output, wall-mount base and circulating pump. Only one accessory or switch contact can be connected to a plug contact at a time.
Applies to: Vitodens 200-W B2HB 45, 57, 160, 199
How to fix control connections and cable routing: step by step
- Route the cables as illustrated so the control unit can move freely.
- Do not secure connecting cables to the control unit bracket.
- Keep cable runs within the maximum permitted cable temperatures.
- Connect accessory power at the control; it switches with the system on/off switch.
- Supply the Vitotronic 200-H HK1B, mixing valve kit and Solartrol from a separate 120 VAC wall receptacle.
- Insert the programming unit into the control unit support, or use a wall mounting base (accessory) near the boiler.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
More commissioning tips for boiler
Source: Vitodens 200-W B2HB installation instructions, p. 46. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.