Viessmann Boiler: Change the reduced (night) room temperature
Change the reduced (night) room temperature on a Viessmann boiler: Sets the room temperature used during the reduced periods. Factory setting is freeze-up protection at 3°C / 37°F, active from 22:00 to 06:00. Adjustable from 4 to 37°C (39 to 99°F). Setting 3°C shows 'Freeze-up protection' in the display.
Applies to: Vitotronic 300 Model GW2
How to fix change the reduced (night) room temperature: step by step
- Open the hinged cover on the programming unit.
- Press the heating circuit selector button so it lights up.
- Press the reduced-temperature button; the current setting flashes.
- Press the up or down button until the required value appears.
- Press OK to confirm; the value stops flashing and is stored.
- Close the hinged cover.
If the unit shows an error code, look it up: Viessmann Boiler codes
More settings shortcuts tips for boiler
Source: Vitotronic 300 GW2 operating instructions, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.