Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Vent routing and combustion air seal

Updated · by Aurora Star Tech Inc.

Vent routing and combustion air seal on a Viessmann boiler: The boiler has a factory fitted vent adaptor. Route the vent to the outdoors on the shortest path with a rising slope. Use the separate venting manual for the vent system itself.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Venting for Vitodens 100-W WB1B

How to fix vent routing and combustion air seal: step by step

  1. Run single-pipe, two-pipe or coaxial venting through the side wall, roof or chimney by the shortest route.
  2. Keep the vent rising at least 3 degrees.
  3. On coaxial installs, remove the plastic centre of the combustion air inlet seal and leave the rubber seal in place.
  4. Follow the Vitodens Venting System Installation Instructions.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More other tips for boiler

Source: Vitodens 100-W WB1B installation manual, p. 17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977