Viessmann Boiler: No domestic hot water (DHW)

Updated · by Aurora Star Tech Inc.

No domestic hot water (DHW) on a Viessmann boiler: The boiler runs but no hot water is delivered. Check power, fuel, settings and any displayed fault in this order.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitocrossal 300 CA3B Dual Fuel boiler with Vitotronic 300 GW6C control

Common causes of no domestic hot water (dhw)

  • Heating system is switched off at the control unit, mains isolator or power distribution board MCB.
  • Control unit or remote control is set incorrectly, or DHW heating is not enabled.
  • No fuel supply (fuel reserves low for NG/LPG, or gas shut-off valve closed for natural gas).
  • A fault is displayed on the control unit.

How to fix no domestic hot water (dhw): step by step

  1. Switch ON the ON/OFF switch on the control units (see page 17).
  2. Switch ON the mains isolator if one is installed outside the boiler room.
  3. Set the MCB in the power distribution board (main domestic MCB) to ON.
  4. Check the operating program, DHW temperature and DHW time program (see page 28).
  5. Check the time setting (see page 30).
  6. For NG/LPG, check the fuel reserves and re-order if required.
  7. For natural gas, open the gas shut-off valve; if needed, check with the gas supply utility.
  8. If the red fault indicator flashes, check the fault type and acknowledge it (see page 34).
  9. Notify the heating contractor if necessary.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

2.53.04.05.06.0CA3B 2.5CA3B 3.0CA3B 3.5CA3B 4.0CA3B 5.0CA3B 6.0CA3B Dual Fuel 2.5CA3B Dual Fuel 2.5 BoilerCA3B Dual Fuel 3.0CA3B Dual Fuel 3.0 BoilerCA3B Dual Fuel 3.5CA3B Dual Fuel 3.5 BoilerCA3B Dual Fuel 4.0CA3B Dual Fuel 4.0 BoilerCA3B Dual Fuel 5.0CA3B Dual Fuel 5.0 BoilerCA3B Dual Fuel 6.0CA3B Dual Fuel 6.0 BoilerCA3B Dual Fuel Series 2.5CA3B Dual Fuel Series 3.0CA3B Dual Fuel Series 3.5CA3B Dual Fuel Series 4.0CA3B Dual Fuel Series 5.0CA3B Dual Fuel Series 6.0Vitocrossal 300 CA3B Dual Fuel 2.5Vitocrossal 300 CA3B Dual Fuel 3.0Vitocrossal 300 CA3B Dual Fuel 3.5Vitocrossal 300 CA3B Dual Fuel 4.0Vitocrossal 300 CA3B Dual Fuel 5.0Vitocrossal 300 CA3B Dual Fuel 6.0Vitocrossal 300 CA3B Dual Fuel Series 2.5Vitocrossal 300 CA3B Dual Fuel Series 3.0Vitocrossal 300 CA3B Dual Fuel Series 3.5Vitocrossal 300 CA3B Dual Fuel Series 4.0Vitocrossal 300 CA3B Dual Fuel Series 5.0Vitocrossal 300 CA3B Dual Fuel Series 6.0

Source: Vitocrossal 300 CA3B Dual Fuel operating instructions, p. 40. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.