Viessmann Boiler: Enable emissions test mode

Updated · by Aurora Star Tech Inc.

Enable emissions test mode on a Viessmann boiler: Coding 8F:1 or 8F:2 allows emissions test mode to be enabled. Coding 8F:0 keeps full menu access. The setting takes effect only when the service menu is exited.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HA, emissions test

How to fix enable emissions test mode: step by step

  1. Set coding 8F to 1 or 2 in the service menu.
  2. Exit the service menu so the coding is active.
  3. Enable emissions test mode from the service menu.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More service & test modes tips for boiler

Source: Vitodens 200-W B2HA 19, 28, 35 Service Instructions, p. 53. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.