Viessmann Boiler: Handling fiberglass wool and ceramic fiber insulation
Handling fiberglass wool and ceramic fiber insulation on a Viessmann boiler: Fiberglass wool and ceramic fiber materials in the boiler (for example the combustion chamber door insulation) can cause respiratory, skin and eye irritation and are a possible cancer hazard when airborne. Use the protection below when handling or cutting them.
Applies to: Vitorond 200 VD2A
How to fix handling fiberglass wool and ceramic fiber insulation: step by step
- Wear a NIOSH-approved dust/mist respirator.
- Wear long-sleeved loose clothing, gloves and eye protection.
- Avoid breathing dust and avoid contact with skin and eyes.
- Wash work clothes separately and rinse the washer thoroughly.
- Expect airborne fibers from sawing, blowing, tear-out or spraying; use extra protection.
- Eyes: flush with lukewarm water for at least 15 minutes, holding the eyelids open.
- Skin: remove soiled clothing, wash with soap and water, and do not rub or scratch.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitorond 200, VD2A Series Service Instructions, p. 3. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.