Viessmann Boiler: Checking burner gasket and flame body assembly
Checking burner gasket and flame body assembly on a Viessmann boiler: Inspect the flame body, electrodes, insulation ring and gasket. Replace only parts that are damaged or worn. If the flame body is replaced, also replace its gasket and fixing screws.
Applies to: B1HE/KE 85/120 and 150/199
How to fix checking burner gasket and flame body assembly: step by step
- Disconnect the ignition electrode plug and remove the electrodes.
- Remove the flame body fixing screws, holding the flame body while doing so.
- Remove the flame body with gasket and thermal insulation ring and check for damage.
- Fit the new burner door gasket with the tab aligned per the diagram.
- Refit the insulation ring and flame body, aligning the door pin with the hole in the flame body.
- 85/120: tighten the Torx screw to 27 lb.in (3.0 Nm).
- 150/199: tighten the 4 Torx screws to 40 lb.in (4.5 Nm). Place the insulation mats, then secure the insulation ring with 3 hex screws to 35 lb.in (4 Nm).
- Check the insulation ring is firmly seated.
- Refit the electrodes, check gaps, and tighten to 40 lb.in (4.5 Nm).
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 51-52. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.