Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Clean the DHW storage tank

Updated · by Aurora Star Tech Inc.

Clean the DHW storage tank on a Viessmann boiler: Visual inspection and cleaning must be done no later than two years after commissioning and then as needed. Do not use hydrochloric acid based cleaners. Use only plastic cleaning tools inside the tank.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DHW storage tank

Common causes of clean the dhw storage tank

  • Loose deposits inside the DHW tank
  • Hard deposits that a high pressure cleaner cannot remove

How to fix clean the dhw storage tank: step by step

  1. Drain the DHW storage tank.
  2. Remove insulation A.
  3. Disconnect the DHW piping from the pipework to stop contamination entering the system.
  4. Remove the tank clean-out cover B.
  5. Remove loose deposits with a high pressure cleaner.
  6. Use a chemical cleaner for hard deposits. Never use hydrochloric acid based agents.
  7. Flush the DHW tank thoroughly.
  8. Refit in reverse order.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitodens 222-F B2TB 19, 35, 68, 125 Service Instructions, p. 26. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair