Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Telephone switch to force heating mode

Updated · by Aurora Star Tech Inc.

Telephone switch to force heating mode on a Viessmann boiler: A short between the remote control terminals switches the heating circuit to heating mode and activates DHW if fitted. When the short is removed, the controller goes back to its set program.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Versatronik 200 heating circuits

How to fix telephone switch to force heating mode: step by step

  1. Connect the switch to terminal 6 with GND at HC1, or to terminal 13 with GND at HC2.
  2. If a remote control is used, connect the switch at the operating module.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More other tips for boiler

Source: Versatronik 200 installation and operating manual, p. 62. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977