How heating curve adjustments change supply temperature on a Viessmann boiler: Changing the slope alters the gradient of the curve. Changing the shift moves the whole curve up or down in parallel. Changing the standard room temperature setpoint offsets the curve along the room temperature axis. The lower the outdoor temperature, the higher the boiler water or supply temperature.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Heating curve settings

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

MW1SVitotronic 300-K, type MW2B

More other tips for boiler

Source: Vitotronic 300-K, MW2C Operating Instructions, p. 34. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.