Viessmann Boiler: Connect burner to control
Connect burner to control on a Viessmann boiler: Standard burner cable connection using the Viessmann quick-connect plug system.
Applies to: Vitotronic 300 KW3 with standard burner
How to fix connect burner to control: step by step
- Connect the RAST-5 plug-in connector to the main circuit board of the control.
- Connect the 7-pole plug to the counter plug of the burner.
- If a vent system accessory is installed, connect the 7-pole plug to the counter plug of the vent system instead.
- Do not connect the 41-plug from the boiler control directly to the burner if a wall vent or flue damper is installed. Follow the vent system instructions.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitotronic 300 installation instructions, p. 17. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.