Viessmann Boiler: Combustion and ventilation air supply (room air dependent)

Updated · by Aurora Star Tech Inc.

Combustion and ventilation air supply (room air dependent) on a Viessmann boiler: The boiler needs fresh air for safe operation and must be in a mechanical room with adequate combustion and ventilation air. The room must not be under negative pressure. Exhaust, attic, or dryer fans can starve the boiler of air.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Room air dependent installations

Common causes of combustion and ventilation air supply (room air dependent)

  • Exhaust, attic, or dryer fans pulling more air than the structure can supply
  • Negative pressure in the boiler room
  • Boiler covered or blocked with debris or stored materials

How to fix combustion and ventilation air supply (room air dependent): step by step

  1. Provide combustion and ventilation air per CAN/CSA-B149.1 or .2, or ANSI Z223.1 combustion air sections.
  2. Install the boiler near an outside wall where practical so fresh air can be ducted directly.
  3. Size ducts per national codes; round ducts are allowed.
  4. Check the boiler area is not under negative pressure and correct it if fans draw too much air.
  5. Keep the boiler uncovered and clear of debris and stored materials that block combustion air.
  6. In closets, check louver free area and enlarge openings as needed.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

399500750100015002000CI2 399CI2 399/500CI2 500CI2 750CI2 750/1000CI2 1000CI2 1500CI2 1500/2000CI2 2000Vitocrossal 200 CI2 399Vitocrossal 200 CI2 500Vitocrossal 200 CI2 750Vitocrossal 200 CI2 1000Vitocrossal 200 CI2 1500Vitocrossal 200 CI2 2000

Source: Vitocrossal 200 CI2 Installation Instructions, pp. 55. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.