Viessmann Boiler: Slab curing (screed drying) function
Slab curing (screed drying) function on a Viessmann boiler: Used to dry a new concrete floor slab with a controlled supply temperature profile. Set F1 to 1 to 4 for profile 1 to 4. Profiles run over 30 days with supply temperatures up to about 50 °C.
Applies to: Mixing valve circuit, screed drying
How to fix slab curing (screed drying) function: step by step
- Set coding F1 to the required profile (1 to 4).
- Follow the slab curing supplier's instructions and local regulations.
- Record heat-up data with the supply temperatures, the maximum supply temperature reached, and the operating condition and outdoor temperature at handover.
- Expect the function to continue after power failure or after the control unit is switched off.
- Heating program restarts after screed drying finishes, or if the address is set manually to 0.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitocontrol-S VD2/CT3/CM2
300-K MW1Vitocontrol-S, VD2/CT3/CM2, 300-K MW1
Vitotronic 100 GC1
Source: Vitocontrol-S, VD2/CT3/CM2 Installation and Service Instructions, p. 180 and 183. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.