Viessmann Boiler: Connect external shut-off (aBÖ) and emergency operation

Updated · by Aurora Star Tech Inc.

Connect external shut-off (aBÖ) and emergency operation on a Viessmann boiler: A dry contact at terminals 16 and 17 gives a controlled switch-off when opened. Use it for safety switch-off only, for example through a limit thermostat. With the contact open, the system has no frost protection and the boiler is not held at minimum water temperature.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: VD2, VD2A and CT3 controls

How to fix connect external shut-off (abÖ) and emergency operation: step by step

  1. Disconnect power before working on the wiring.
  2. Remove the jumper between terminals 16 and 17.
  3. Connect a dry contact to the terminals.
  4. For emergency operation, move the jumper from terminals 16 and 17 to terminals 17 and 18.
  5. See the controlled switch-off pages (52 to 59) for details.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

GC1KW10B

Source: Vitotronic 100 GC1 installation and service instructions, p. 75. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.