Viessmann Boiler: Open the control unit and power pump module
Open the control unit and power pump module on a Viessmann boiler: The boiler ON/OFF switch does not disconnect power to the power/pump module. Turn off the main service switch or breaker before opening the module.
Applies to: Vitodens 100-W WB1B control unit and power pump module
How to fix open the control unit and power pump module: step by step
- Turn off the main service switch or breaker.
- Loosen the screws underneath the boiler without removing them, then remove the cover.
- Pull the tabs outward.
- Flip the control unit down.
- Remove the cover by releasing the tabs if necessary.
- Unlock the 4 spring-loaded lock screws (B) and remove the power pump module cover plate.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Viessmann Vitodens 100-W WB1B installation and service manual, p. 50. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.