Viessmann Boiler: Multi-circuit layout with mixing valves and one unmixed circuit
Multi-circuit layout with mixing valves and one unmixed circuit on a Viessmann boiler: Layout for a boiler with DHW tank, low-loss header, several heating circuits with mixing valves and one circuit without a mixing valve. Viessmann recommends contacting the local sales representative for design help. The Vitotronic 200-H HK1B mixing valve control with LON module can replace the accessory kit and Vitocontrol.
Applies to: Vitodens 200-W B2HB with Vitotronic 200, HO1B outdoor reset control, system layout 9
How to fix multi-circuit layout with mixing valves and one unmixed circuit: step by step
- Locate the expansion tank so it can be reached and serviced, as the diagram shows.
- Pipe pumps C and K so they pump into the boiler, as illustrated.
- Fit the Viessmann temperature sensor on the low-loss header.
- Fit mixing valve temperature sensors on each mixing circuit.
- Set the heating circuit pump 28/20 function through coding address 53.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
Source: Vitodens 200-W B2HB 19 to 35, 68 to 125 Installation Instructions, p. 41. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.