Viessmann Boiler: Flow switch check
Flow switch check on a Viessmann boiler: The B2TB has a flow sensing device. If flow is too low the switch opens, the burner shuts down, and it will not restart until adequate flow returns.
Applies to: Vitodens 222-F B2TB 19, 35, 68, 125
How to fix flow switch check: step by step
- Throttle the water flow to or from the boiler.
- Confirm the boiler shuts down once flow drops below its safe operating set point.
- Restore flow and confirm the burner restarts.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
222-F B2TB 19222-F B2TB 35222-F B2TB 68222-F B2TB 125B2TB 19B2TB 35B2TB 68B2TB 125VD2T 1HC1T4ZP.01VD2T 1HC1T4ZV.01Vitodens 222-F, B2TB 19Vitodens 222-F, B2TB 35Vitodens 222-F, B2TB 68Vitodens 222-F, B2TB 125
More service & test modes tips for boiler
Source: Vitodens 222-F, B2TB service instructions, p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.