Viessmann Boiler: System layout 1: one heating circuit
System layout 1: one heating circuit on a Viessmann boiler: Basic layout with the boiler and one heating circuit. Heating circuit should be designed for 30 to 40 F (16.7 to 22.2 C) rise. For a lower design rise, use layout 3 or 4.
Applies to: Vitodens 100-W WB1B 26 and 35
How to fix system layout 1: one heating circuit: step by step
- Fit an air vent and pressure relief valve on the system.
- Fit the heating circuit pump and expansion tank as shown.
- Fit a pressure activated by-pass if components in the heating circuit can isolate the pump flow.
- Use a low-loss header if flow is below 1.7 GPM (400 L/h) or above 6.2 GPM (1400 L/h).
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 100-W, WB1B CombiPlus Installation & Service Instructions, p. 38. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.