Viessmann Boiler: Routine cleaning and maintenance
Routine cleaning and maintenance on a Viessmann boiler: Maintenance intervals from the owner guide. Only qualified or authorised contractors should carry out internal work.
Applies to: Vitodens 100-W B1HE/B1KE
How to fix routine cleaning and maintenance: step by step
- Clean the boiler annually, since contamination raises flue gas temperature and energy losses.
- Clean the operating unit surface with a microfiber cloth and a non-scouring domestic cleaner.
- Have the DHW tank and its connections cleaned by a qualified contractor no later than 2 years after commissioning, then as required.
- Check the temperature and pressure relief valve every six months by venting it. Water may drip during heat-up.
- Do not close the safety valve. Overpressure can cause damage.
- For a potable water filter: replace the element every six months on non-back-flushing filters, with a visual check every two months. On back-flushing filters, back flush every two months.
- Have the system serviced by an authorised contractor at least every 2 years.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 100-W B1HE/B1KE operating instructions, p. 31. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.