Updated · by Aurora Star Tech Inc.

System layout 1: DHW tank, mixing valve and radiator loops on a Viessmann boiler: Layout 1 uses one boiler with a DHW storage tank, one heating circuit without a mixing valve, and two heating circuits with a mixing valve: a high-temperature radiator loop and a low-temperature underfloor loop. The 3-way mixing valve is controlled by an accessory kit. Underfloor systems with non-oxygen diffusion barrier tubing need system separation, and all components on the secondary side must be corrosion-resistant. A hydronic pressure bypass may be required with single-speed pumps. All pumps are field supplied.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitocrossal 300 CA3B Dual Fuel with DHW tank and two heating circuits

How to fix system layout 1: dhw tank, mixing valve and radiator loops: step by step

  1. Install the boiler supply and return with the mixing valve and its temperature sensor.
  2. Connect the outdoor sensor, DHW tank sensor and system supply sensor as shown in the layout.
  3. Fit a hydronic pressure bypass if single-speed boiler or system pumps are used.
  4. Confirm the DHW and heating circuit pumps are field supplied and correctly sized.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

2.53.04.05.06.0CA3B 2.5CA3B 3.0CA3B 3.5CA3B 4.0CA3B 5.0CA3B 6.0CA3B Dual Fuel 2.5CA3B Dual Fuel 2.5 BoilerCA3B Dual Fuel 3.0CA3B Dual Fuel 3.0 BoilerCA3B Dual Fuel 3.5CA3B Dual Fuel 3.5 BoilerCA3B Dual Fuel 4.0CA3B Dual Fuel 4.0 BoilerCA3B Dual Fuel 5.0CA3B Dual Fuel 5.0 BoilerCA3B Dual Fuel 6.0CA3B Dual Fuel 6.0 BoilerCA3B Dual Fuel Series 2.5CA3B Dual Fuel Series 3.0CA3B Dual Fuel Series 3.5CA3B Dual Fuel Series 4.0CA3B Dual Fuel Series 5.0CA3B Dual Fuel Series 6.0Vitocrossal 300 CA3B Dual Fuel 2.5Vitocrossal 300 CA3B Dual Fuel 3.0Vitocrossal 300 CA3B Dual Fuel 3.5Vitocrossal 300 CA3B Dual Fuel 4.0Vitocrossal 300 CA3B Dual Fuel 5.0Vitocrossal 300 CA3B Dual Fuel 6.0Vitocrossal 300 CA3B Dual Fuel Series 2.5Vitocrossal 300 CA3B Dual Fuel Series 3.0Vitocrossal 300 CA3B Dual Fuel Series 3.5Vitocrossal 300 CA3B Dual Fuel Series 4.0Vitocrossal 300 CA3B Dual Fuel Series 5.0Vitocrossal 300 CA3B Dual Fuel Series 6.0

Source: Viessmann Vitocrossal 300 CA3B Dual Fuel installation manual, p. 46. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.