Viessmann Boiler: Mixing valve motor rotation check

Updated · by Aurora Star Tech Inc.

Mixing valve motor rotation check on a Viessmann boiler: When the mixing valve opens, the supply temperature must rise. If it drops, the motor is turning the wrong way or the valve set is fitted incorrectly.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Mixing valve heating circuits

Common causes of mixing valve motor rotation check

  • Motor turning in the wrong direction
  • Mixing valve set incorrectly fitted

How to fix mixing valve motor rotation check: step by step

  1. Run the mixing valve open in the actuator test.
  2. Watch the supply temperature while the valve opens.
  3. If the temperature falls, check the motor rotation direction.
  4. Check the mixing valve fitting against the mixing valve installation instructions.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

Vitotronic 200

HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B

Vitotronic 300-K

MW1SVitotronic 300-K, type MW2B

Source: Vitotronic 200 and 300-K Installation and Service Instructions, p. 31. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977