Viessmann Boiler: Set the adjustable high limit to 189 ºF / 87 ºC
Set the adjustable high limit to 189 ºF / 87 ºC on a Viessmann boiler: Change the dial stop on the adjustable high limit selector knob.
Applies to: Vitotronic 300 adjustable high limit
How to fix set the adjustable high limit to 189 ºf / 87 ºc: step by step
- Lever out the selector knob behind the hinged cover with a suitable screwdriver.
- Break off the respective cams on the dial with pointed pliers.
- Refit the selector knob so the marking sits between 75 and 90.
- Turn the selector knob fully clockwise.
- Check the box in the Vitotronic 300 service instructions.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitotronic 300 installation instructions, p. 22. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.