Viessmann Boiler: System Layout 1: direct-connected heating circuit with DHW
System Layout 1: direct-connected heating circuit with DHW on a Viessmann boiler: Radiator (high-temp.) heating circuit and DHW production. Flow in the heating circuit is less than the boiler maximum flow.
Applies to: Radiator circuit plus DHW tank
How to fix system layout 1: direct-connected heating circuit with dhw: step by step
- Confirm the heating circuit flow is below the boiler maximum water flow rate.
- Use a low-loss header if the flow may exceed the maximum or is unknown.
- Run the DHW circulating pump into the boiler as shown.
- Set the DHW recirculation pump function by coding address 53 if used.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
Source: Vitodens 200-W, B2HB technical data manual, p. 34. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.