Viessmann Boiler: Accessing the control unit and wiring
Accessing the control unit and wiring on a Viessmann boiler: Access the control unit through the external accessory connection box. Power requires a 120 VAC / 12 A supply.
Applies to: Vitodens 200-W B2HB 45, 57, 160, 199
How to fix accessing the control unit and wiring: step by step
- Remove both screws from the junction box cover and set them aside.
- Loosen both retaining screws (do not remove them).
- Pull the external accessory connection box forward until the screws clear the rail guides.
- Swing the connection box down.
- Tilt the bottom of the cover forward, lift it off the locating pins and set it aside.
- Close both sides of the programming unit cover.
- Release the hinged hooks on both sides of the control unit.
- Lift the control unit cover and fold the control unit down.
- Release the locking tabs and remove the cover.
- Route all connecting cables to their areas and secure them to the control base at the existing strain reliefs.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
Source: Vitodens 200-W B2HB installation manual, p. 22-24. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.