Updated · by Aurora Star Tech Inc.

Installing the control unit front on a Viessmann boiler: Close the control unit front and connect the Optolink and programming unit.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitotronic 100 GC1

How to fix installing the control unit front: step by step

  1. Position the front housing and clip the hinges onto the counter-parts on the main housing.
  2. Release the stay bar, open it and lock it at point A.
  3. Insert the flat cable from the Optolink into plug X20.
  4. Insert the programming unit plug into plug X10, routing it through the cable guides in the cover.
  5. Engage the stay bar in the front housing.
  6. Close the front housing and secure it with the supplied screws.
  7. Install the connection enclosure cover and support it with the supplied screw.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

Vitotronic 100, type GC1

More other tips for boiler

Source: Vitotronic 100 GC1 / Vitotronic 300-K MW1S installation and service instructions, p. 54. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.