Viessmann Boiler: Check fuse F1

Updated · by Aurora Star Tech Inc.

Check fuse F1 on a Viessmann boiler: Procedure to check the 120 V control fuse F1 in the junction box.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 100-W B1HE/B1KE

How to fix check fuse f1: step by step

  1. Turn off the ON/OFF switch.
  2. Depending on the configuration, move the programming unit with its bracket to the maintenance position.
  3. Remove cover A.
  4. Check fuse F1 against the connection and wiring diagram.
  5. Insert fuses without force and seat them correctly. Only use the same structural type with the specified response characteristic (6.3 A slow, 120 V).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitodens 100-W B1HE/B1KE installation manual, p. 89. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.